After this lesson you can

  • Write a protocol with metadata, requirements, labware, a pipette and liquid-handling commands
  • Choose robotType and apiLevel, and say why a Flex and an OT-2 differ
  • Use transfer, distribute and consolidate, and say what each one does with tips
  • Simulate a protocol, read the run log and tell the real steps from the summary lines
  • Turn a simulator run into an automatic test in git

Read these first

Supports: this track, and the Developer path (tests and a pipeline for anything that drives hardware). Time: about three hours. Simulation only: nothing in this lesson runs on a robot.

1. Why this matters

A liquid-handling robot does what its protocol says, every time, without asking. That is why a protocol must be checked before it runs. A wrong volume or well is not a typing mistake. It is a ruined plate, or worse.

Opentrons publishes an open Python interface for its robots, the Python Protocol API, and a free simulator. A protocol is a Python file, so you can keep it in git, review it, test it in a pipeline and have an agent draft it. The simulator runs your protocol on a computer, with no robot, and prints each step the robot would take. You read that log before anything else.

By the end you will have a protocol that mixes three dyes in a plate, a log you can read, and a test that fails when the protocol breaks. In lesson 6 a program writes one such protocol per round.

Remember lesson 1. A clean simulation means the commands are valid. It does not mean the protocol is safe.

What the PDM decides here

You decide You may delegate to an agent You verify Other disciplines involved
What the protocol must do, which robot and API level it targets, and what counts as a correct run Drafting the protocol code and its test, from a written brief The simulator log, line by line, against the brief; that the API level and labware names exist in the current docs The lab’s supervisor (real runs), a biosafety officer, security (who may change a protocol)

2. Key ideas

A protocol is a Python file with a fixed shape

Every protocol has three parts.

  1. metadata: a dictionary of names and notes, such as protocolName and author.
  2. requirements: a dictionary with the robot type and the API level.
  3. run: a function that receives a ProtocolContext, usually called protocol. Everything the robot does happens inside it.

robotType and apiLevel

The API level is the version of the Protocol API your file is written for. Opentrons states two rules in its docs. Declare the level in one place only: in requirements (from version 2.15 on) or in metadata. If you put it in neither, or in both, the protocol will not simulate or run. And a robot can only run a protocol whose level its software supports. A lower level runs on more software versions.

The robot type is "Flex" or "OT-2". For the Flex you must say so in requirements. For the OT-2 it is optional.

The ceilings change with each software release. The docs list these ranges for robot software 10.0.0:

Robot API levels
Flex 2.15 to 2.30
OT-2 2.0 to 2.28

Check the current versioning page before you pick a level. Do not copy a number from this lesson or from an agent.

There is one practical catch. The opentrons package on PyPI, version 10.1.0 when this was written, simulated a Flex protocol at level 2.30. It refused an OT-2 protocol, with an error saying the protocol was designed for an OT-2 robot. An older release, 9.0.0, simulated the OT-2 file. If you target an OT-2, check which package version supports it.

Labware, pipettes and the deck

  • Labware is anything that holds liquid or tips: a tip rack, a reservoir, a well plate. You load it with protocol.load_labware(name, slot). The name is an exact string from the Opentrons labware library, such as nest_96_wellplate_200ul_flat. A typo is an error.
  • Slots are named differently on the two robots. The Flex uses A1 to D3. The OT-2 uses numbers 1 to 11.
  • A pipette is loaded with protocol.load_instrument(name, mount, tip_racks=[...]). The name must match the pipette, such as flex_1channel_1000 on a Flex or p300_single_gen2 on an OT-2.
  • A trash bin. The Flex example below loads one with protocol.load_trash_bin("A3"), so the pipette has somewhere to drop tips.

Wells are addressed like a spreadsheet: plate["A1"] is one well, plate.columns()[0] is column 1 from A to H, and plate.rows()[0] is row A.

Three liquid-handling commands

The API has simple commands, such as aspirate and dispense. It also has three complex commands that wrap many of them. These are the ones you will use most.

Command What it does Typical use
transfer Moves a volume from one place to another, one source to one destination, or in lists One dye into one well
distribute Takes liquid from one source and dispenses it to many destinations Water into a whole column
consolidate Takes liquid from many sources and dispenses it to one destination Pooling wells into one

Two settings matter. new_tip says when to change tips: "once", "always" or "never". For different liquids, use "always", or one dye carries into the next. mix_after=(3, 40) mixes three times with 40 microlitres in the destination well after dispensing.

If the total is more than one tip can hold, these commands split the job into several trips. distribute also keeps a small disposal volume in the tip and blows it out afterwards. The log in the worked example shows it.

A volume may be a single number or a list, one per destination. That is how a program can give each well its own recipe. You use that in lesson 6.

Simulate: what it shows and what it does not

You run the simulator on your own computer:

opentrons_simulate protocol.py

You can also run it as a module with python -m opentrons.simulate protocol.py, which is useful inside a test. Both print a run log: one line per action, indented to show what belongs to what. A protocol that works exits with code 0. A failing one prints an error and exits with a non-zero code.

The simulator tells you that the file loads, the API level is accepted, names exist, slots do not clash and every command is valid. The log shows which tip, source, destination and volume each step uses.

The simulator does not tell you that the liquid behaves as you hope, that the volumes suit your assay, that a person can safely load and clear the machine, or that the real robot has the labware, calibration and software the protocol expects.

The Opentrons App also analyses a protocol when you import it. The OT-2 docs say it turns the file into robot commands and warns you about errors. Treat that as a second check. You do not need the app for this track.

Set up one environment for the whole track

Make a virtual environment and install the packages for the whole track in one command. Later lessons add Ax and BoTorch. If you install them in a second step, the installer may change the version of numpy and break the Opentrons simulator. The error looks like cannot import name 'trapz' from 'numpy'. One command lets the installer find versions that work together.

python3 -m venv .venv
source .venv/bin/activate
pip install opentrons ax-platform matplotlib pytest

The code in this track was tested with opentrons 10.1.0, ax-platform 1.3.1, BoTorch 0.18.1 and Python 3.12. Ax asks for Python 3.11 or newer. With newer versions, expect small changes.

3. Step by step

  1. Pick the robot and the level. Write them in requirements. Check the versioning page for the current range.
  2. Write the metadata. Add “Simulation only” until a supervisor approves a real run.
  3. Load the labware with exact names from the labware library, each in its own slot.
  4. Load the pipette and give it the tip rack.
  5. Write the steps with transfer, distribute and consolidate. Set new_tip on purpose.
  6. Simulate. If it fails, read the last line of the error first.
  7. Read the log. Check each volume, well and tip against what you meant. Count the tips.
  8. Save the log and write a test that simulates every protocol in the folder.
  9. Commit the protocol, the log and the test together.

4. Worked example: three dyes in one plate

Here is a Flex protocol for the colour-mixing lab. It fills column 1 with water, adds three dyes to well A2 one at a time, and pools three wells into another. It uses made-up dye names and no real liquids. It is simulation only.

from opentrons import protocol_api

metadata = {
    "protocolName": "Three dyes, one plate",
    "author": "A. Learner",
    "description": "Water, three dyes and a pooled well. Simulation only.",
}

requirements = {"robotType": "Flex", "apiLevel": "2.30"}


def run(protocol: protocol_api.ProtocolContext):
    # Labware. Flex deck slots are named A1 to D3.
    tips = protocol.load_labware("opentrons_flex_96_tiprack_200ul", "D1")
    reservoir = protocol.load_labware("nest_12_reservoir_15ml", "D2")
    plate = protocol.load_labware("nest_96_wellplate_200ul_flat", "D3")
    protocol.load_trash_bin("A3")

    # Pipette: single-channel, 5 to 1000 uL, on the left mount.
    pipette = protocol.load_instrument("flex_1channel_1000", "left", tip_racks=[tips])

    column = plate.columns()[0]  # A1 to H1, top to bottom

    # One source, many wells: one tip, one aspirate per refill.
    pipette.distribute(90, reservoir["A1"], column)

    # One dye into one well, a fresh tip for each dye, then mix.
    for dye_well in ("A2", "A3", "A4"):
        pipette.transfer(
            20,
            reservoir[dye_well],
            plate["A2"],
            new_tip="always",
            mix_after=(3, 40),
        )

    # Many sources, one well: pool three wells into one.
    pipette.consolidate(30, [plate["A1"], plate["B1"], plate["C1"]], plate["D2"])

Run opentrons_simulate mix_dyes.py. It exits with code 0 and prints 66 lines. The first two say that a settings file and belt calibration were not found and defaults load. That is normal on a computer with no robot. Then each command prints a summary line at the left margin, with its steps indented below:

Distributing 90.0 from A1 of NEST 12 Well Reservoir 15 mL on slot D2 to A1 of NEST 96 Well Plate 200 µL Flat on slot D3
	Transferring 90.0 from A1 of NEST 12 Well Reservoir 15 mL on slot D2 to A1 of NEST 96 Well Plate 200 µL Flat on slot D3
		Picking up tip from A1 of Opentrons Flex 96 Tip Rack 200 µL on slot D1
		Aspirating 185.0 uL from A1 of NEST 12 Well Reservoir 15 mL on slot D2 at 716.0 uL/sec
		Dispensing 90.0 uL into A1 of NEST 96 Well Plate 200 µL Flat on slot D3 at 716.0 uL/sec
		Dispensing 90.0 uL into B1 of NEST 96 Well Plate 200 µL Flat on slot D3 at 716.0 uL/sec
		Blowing out into Trash Bin on slot A3 at 716.0 uL/sec

Look at the numbers. You asked for 90 microlitres per well. The robot aspirates 185. That is two doses of 90 plus 5 for the disposal volume. Then it dispenses 90 twice and blows out the rest. Eight wells need four such trips. Someone who reads only the protocol would not see this. Someone who reads the log does.

Each dye step shows Picking up tip and Dropping tip, because new_tip="always". The mixing shows three aspirate and dispense pairs of 40 microlitres. The last block pools: three aspirates of 30 from A1, B1 and C1, then one dispense of 90 into D2.

Now break it on purpose. Change the plate name to nest_96_wellplate_200ul_flatt. The simulator stops and prints:

ProtocolCommandFailedError [line 16]: Error 4000 GENERAL_ERROR (ProtocolCommandFailedError): PythonException: FileNotFoundError: Labware "nest_96_wellplate_200ul_flatt" not found with version 1 in namespace "opentrons".

Put a second plate in slot D3 and you get:

ProtocolCommandFailedError [line 17]: Error 4000 GENERAL_ERROR (ProtocolCommandFailedError): LocationIsOccupiedError: Labware nest_96_wellplate_200ul_flat is already present at slotName=<DeckSlotName.SLOT_D3: 'D3'>.

Each error names the line and the cause. Agents make exactly these mistakes, and the simulator catches them in a second.

Finally, a test. Save it as tests/test_protocols.py beside a protocols/ folder:

import subprocess
import sys
from pathlib import Path

PROTOCOLS = sorted(Path(__file__).parent.parent.glob("protocols/*.py"))


def simulate(protocol: Path) -> subprocess.CompletedProcess[str]:
    return subprocess.run(
        [sys.executable, "-m", "opentrons.simulate", str(protocol)],
        capture_output=True,
        text=True,
        check=False,
    )


def test_there_is_a_protocol() -> None:
    assert PROTOCOLS, "no protocols found"


def test_every_protocol_simulates() -> None:
    for protocol in PROTOCOLS:
        result = simulate(protocol)
        assert result.returncode == 0, f"{protocol.name} failed:\n{result.stderr}"

Run pytest. Both tests pass. You can also read result.stdout in a test and check a fact that matters, such as the volume in the pooled well. That tests the plan, not only the syntax.

If you have an OT-2

The same protocol for an OT-2 uses numeric slots, a different tip rack and pipette, and no trash-bin call:

requirements = {"robotType": "OT-2", "apiLevel": "2.28"}

tips = protocol.load_labware("opentrons_96_tiprack_300ul", 1)
reservoir = protocol.load_labware("nest_12_reservoir_15ml", 2)
plate = protocol.load_labware("nest_96_wellplate_200ul_flat", 3)
pipette = protocol.load_instrument("p300_single_gen2", "left", tip_racks=[tips])

Remember the catch above: this file simulated under opentrons 9.0.0 and was refused under 10.1.0.

5. Working with AI agents on this

What the PDM decides. The goal, the robot and API level, and the acceptance test: “the simulator exits with code 0 and the log shows these volumes in these wells”.

What you delegate, and the exact brief. You may hand an agent the whole file and its test. This is the delegate rung: a written brief, acceptance criteria and your review.

Task: write an Opentrons protocol and a pytest test. Simulation only.
Target: robotType Flex, apiLevel 2.30. Check the versioning page first:
https://docs.opentrons.com/python-api/versioning/ and tell me if 2.30 is not valid.

The protocol: water (reservoir A1) into every well of column 1 of a
96-well plate, 90 uL each. Then dyes from reservoir A2, A3, A4, 20 uL each,
into plate well A2, with a new tip for each dye.

Rules:
1. Use only labware and pipette names from the Opentrons docs. List each
   name and where you found it.
2. Declare apiLevel in `requirements` only.
3. Do not invent API methods. If unsure, say so and cite the docs page.
4. Run `opentrons_simulate` and paste the last 20 lines of its output.
5. Add a test that simulates every file in protocols/ and checks exit code 0.
6. Write nothing for real equipment or real liquids.
Output: the protocol file, the test file, the simulator output.

How you verify. Do not trust the agent’s pasted output. Run the simulator yourself and read the log. Check each volume and well against your brief. Count the tips. Look up every labware name and method in the docs. Agents often use calls from an older version or the wrong robot. The simulator catches an invalid call, but not a wrong volume that is still valid.

Which disciplines are involved. The lab supervisor decides whether a real run is ever allowed. Security asks who can change a protocol and how you would know.

Where this sits on the ladder. This is delegate. It becomes orchestrate when several agents write protocols for several experiments at once. Then you need one test that all of them must pass. A merge request check that runs the simulator on every changed protocol, and blocks the merge on a failure, is the govern rung.

Disclose. Add to the README: “The protocol and test were drafted by an AI agent from my brief. I ran the simulator myself and read the whole log.” See Disclose AI use.

6. Common mistakes

  • Copying an API level from memory. Check the versioning page. The valid range changes.
  • Declaring the level twice, or never. Use one place.
  • Mixing up Flex and OT-2. Slot names, tip racks and pipette names differ.
  • Installing packages in two steps. A later install can change numpy and break the simulator. Install all at once.
  • Reusing a tip across dyes. Set new_tip="always" when liquids must not mix.
  • Skipping the log. Exit code 0 only means the commands were valid. Reading the volumes is your job.

7. Practice: a simulated protocol with a test

Deliverable: a folder in your git repository, lab/protocols/, containing a protocol, its simulator log and a test.

  1. Write a protocol for your robot type that loads a tip rack, a 12-well reservoir and a 96-well plate. Use distribute for one liquid, transfer with new_tip="always" for at least two others and consolidate once.
  2. Simulate it. Save the output with opentrons_simulate lab/protocols/mix.py > lab/protocols/mix.sim.log.
  3. In lab/protocols/NOTES.md, answer in three sentences: how many tips did it use, why did distribute aspirate more than the doses add up to, and what would the simulator not show?
  4. Add tests/test_protocols.py from the lesson and make it pass.
  5. Break the protocol twice (a labware typo, a slot clash). Paste each error into the notes.
  6. Commit all of it with a message such as feat: add simulated mixing protocol and test.

Check: ask an agent to write the same protocol from your brief. Simulate it and list every difference between its log and yours.

8. Checklist

  • robotType and apiLevel are in requirements, and not in metadata.
  • I checked the level against the current versioning page.
  • Every labware and pipette name is exact, and I looked each one up.
  • new_tip is set on purpose for each liquid.
  • The simulator exits with code 0 and I read the whole log.
  • The log is saved next to the protocol.
  • A test simulates every protocol in the folder.
  • The protocol says “Simulation only” until a supervisor approves a real run.
  • I recorded my AI use.

9. Further learning

Start with the Opentrons Python API tutorial, then read the complex commands page on tip handling and disposal volume. The page on executing and simulating lists the simulator’s options. The OT-2 import page shows what the app does with a file. Keep the Python Protocol API documentation open. Next, in Design an experiment, you decide what the protocol should run, before you write another line of it.

Finished this lesson?

This is only for you. It is saved in this browser, on this device, and nothing is sent anywhere. It is not a grade and not a certificate.

Go deeper

Further learning

Free or low-cost material from other publishers. We opened every link; check the cost label before you start.

Back to the track: Lab automation in code